25 kW pellet heating with a larger thermal store
The package contains 1 storage connection kit, one per buffer tank. For pressure maintenance, the package contains 1 × 80-liter heating expansion vessel including suitable cap valves. The total vessel volume of 80 liters corresponds to at least 10 percent of the nominal buffer volume. The specialist contractor calculates the final pressure maintenance based on the entire system including the boiler and pipe network.
Automatic operation takes care of recurring manual steps
Pellet feed and ignition run automatically. Burner cleaning, heat exchanger cleaning and ash removal are also part of the boiler equipment. You still empty the externally accessible ash container yourself. The integrated standard container holds 135 liters or approximately 82 kg of wood pellets; an external pellet feed system is not included.
Operate heating mode via touchscreen
The APC-CENTER controller offers a color touchscreen and can control up to six pumps and two heating circuit mixers. Remote access is possible via the integrated LAN internet module once the connection has been set up. A distinction must be made between the controller and the pumps and heating circuits actually installed: a complete heating circuit manifold with mixer circuits is not part of the package.
Store heat and prepare connections
Its 100 mm EPS insulation limits heat losses. The boiler connection package supplements the return temperature elevation with a high-efficiency pump, boiler safety group, dirt trap and connection fittings. The package contains 1 × 800-liter buffer tank, without heat exchanger and with 100 mm insulation. The nominal buffer volume totals 800 liters. This nominal volume is used for package sizing; the actual heating water content of the tanks totals 714 liters.
What should be clarified before ordering
The specialist contractor checks the heating load, the installation route, the footprint, the flue system and the hydraulic concept. The basic package contains the listed components and connection fittings. System-dependent piping, sealing material, transitions, heating circuit distribution, flue system as well as installation and commissioning are planned separately. The buffer tank is not a domestic hot water cylinder.
Illustrations are examples; the listed scope of delivery is authoritative.
Recommended and optional accessories
Scope of delivery
- 1 × DEFRO Epsilon F 25 pellet boiler, standard version with 135-liter pellet container (approx. 82 kg pellets)
- 1 × 800-liter buffer tank, without heat exchanger, with 100 mm insulation
- 1 × 80-liter heating expansion vessel, including suitable cap valves
- Boiler equipment: Integrated APC-CENTER controller with color touchscreen, weather-compensated control function and LAN internet module
- Boiler equipment: Integrated pellet feed system and pellet burner with automatic cleaning as well as two TSS ignition elements
- Boiler equipment: Automatic heat exchanger cleaning with turbulators and automatic ash removal with ash container
- Boiler equipment: Induced draft fan as well as integrated flue gas, negative pressure and pellet fill level sensors
- Boiler equipment: Cleaning tool, adjustable feet and transport handle
- Boiler equipment: Flue pipe extension from 100 to 130 mm
- Boiler equipment: Boiler assembly and operating instructions as well as controller operating instructions
- Connection package DEFKAP: 1 × Suitable return temperature elevation with suitable high-efficiency pump, thermometers and insulation; make and version may change depending on availability
- Connection package DEFKAP: 1 × KSG1 - Boiler safety group 1 inch, up to 50 kW
- Connection package DEFKAP: 1 × KFEH12 - Boiler fill and drain cock 1/2 inch, brass
- Connection package DEFKAP: 1 × DN2801S - Double nipple black 1 inch
- Connection package DEFKAP: 1 × DN280114S - Double nipple black 1 1/4 inch
- Connection package DEFKAP: 1 × RN1120S - Pipe nipple black 1 inch x 120 mm
- Connection package DEFKAP: 2 × SM1 - Welding socket black 1 inch
- Connection package DEFKAP: 1 × T1301S - T-piece black 1 inch
- Connection package DEFKAP: 1 × W921S - Elbow black 1 inch, 90 degrees, female/male thread
- Connection package DEFKAP: 1 × SF114 - Dirt trap 1 1/4 inch, brass
- Connection package PAEPS2: 1 × EXSEL12 - Quick vent with shut-off 1/2 inch
- Connection package PAEPS2: 1 × KFEH12 - Boiler fill and drain cock 1/2 inch, brass
- Connection package PAEPS2: 4 × KGH1 - Universal ball valve 1 inch with red lever
- Connection package PAEPS2: 2 × EXBIZ - Bimetal pointer thermometer with immersion sleeve 1/2 inch, 0-120 °C, diameter 63 mm
- Connection package PAEPS2: 5 × DN2801S - Double nipple black 1 inch
- Connection package PAEPS2: 4 × RST2411121S - Reducer black 1 1/2 x 1 inch
- Connection package PAEPS2: 1 × RST24111412S - Reducer black 1 1/4 x 1/2 inch
- Connection package PAEPS2: 6 × ST290112S - Plug black 1 1/2 inch
- Connection package PAEPS2: 2 × ST29012S - Plug black 1/2 inch
- Connection package PAEPS2: 1 × T1301121S - T-piece reduced black 1 x 1/2 x 1 inch
- Connection package PAEPS2: 6 × PSIS - Buffer connection insulation for 1 1/2-inch connections
- Connection package PAEPS2: 1 × Assembly/hydraulic diagram