{"product_id":"luft-wasser-waermepumpe-titan-therm-terma-18-kw-230-v","title":"Air-water heat pump TERMA","description":"\u003ch2\u003eAir-to-water heat pump\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eHeat pump for heating and domestic hot water preparation, type TERMA\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003cimg style=\"float: none;\" alt=\"Air-to-water heat pump TERMA\" src=\"https:\/\/gemashop.de\/cdn\/shop\/files\/WPE_240x240.png\" data-original=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0757\/7796\/6428\/files\/WPE_240x240.png?v=1721997810\" data-files=\"WPE.png\" loading=\"lazy\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003c\/div\u003e\n\u003cp\u003e\u0026nbsp;\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAn air-to-water heat pump is capable of extracting heat from the ambient air even at low temperatures down to minus 20 degrees Celsius.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThis is because even at this temperature, the refrigerant used evaporates.\u003c\/p\u003e\n\u003cp\u003eAn\u003cstrong\u003e air-to-water heat pump\u003c\/strong\u003e uses the ambient air as a heat source to supply an entire building with heat. During operation, a built-in fan actively draws in the air and directs it to a heat exchanger, the evaporator. A refrigerant circulates in this, which, due to its thermal properties, changes its state of aggregation even at low temperatures. When it comes into contact with the supplied “warm” outside air, it heats up until it finally begins to evaporate. Since the temperature of the resulting vapor is still relatively low, the vapor flows on to an electrically driven compressor. This increases the pressure, which also raises the temperature. Once the refrigerant vapor has reached the desired temperature level, it flows on to the next heat exchanger, the condenser. Here it transfers its heat to the heating system and condenses.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eHeat pump\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eThe heat thus gained can be used for heating or for hot water preparation. Before the cooled refrigerant can be heated and compressed again, it first flows through an expansion valve. The pressure and temperature drop to the initial level and the cycle can be repeated.\u003c\/p\u003e\n\u003ch3 style=\"text-align: left;\"\u003eThe TERMA air-to-water heat pump is the optimal solution for your home\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli style=\"text-align: left;\"\u003eenvironmentally friendly\u003c\/li\u003e\n\u003cli style=\"text-align: left;\"\u003eenergy efficient\u003c\/li\u003e\n\u003cli style=\"text-align: left;\"\u003eeligible for funding\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 style=\"text-align: left;\"\u003e\u003c\/h3\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\n\u003ch3\u003eTechnical data: air-to-water heat pump\u003c\/h3\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\n\u003ctable class=\"tableizer-table\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"tableizer-firstrow\"\u003e\n\u003cth\u003eType monobloc\u003c\/th\u003e\n\u003cth\u003eModel BLN-012TA1\u003c\/th\u003e\n\u003cth\u003eModel BLN-018TA1\u003c\/th\u003e\n\u003cth\u003eBLN-018TA3\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated voltage\u003c\/td\u003e\n\u003ctd\u003e220-240V\/50 Hz\u003c\/td\u003e\n\u003ctd\u003e220-240V\/50 Hz\u003c\/td\u003e\n\u003ctd\u003e400V\/50 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePerformance parameters at A7\/W35\u003c\/td\u003e\n\u003ctd\u003e\u0026nbsp;\u003c\/td\u003e\n\u003ctd\u003e\u0026nbsp;\u003c\/td\u003e\n\u003ctd\u003e\u0026nbsp;\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal heat output (kW)\u003c\/td\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003ctd\u003e18\u003c\/td\u003e\n\u003ctd\u003e18\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower input (kW)\u003c\/td\u003e\n\u003ctd\u003e2.6\u003c\/td\u003e\n\u003ctd\u003e3.81\u003c\/td\u003e\n\u003ctd\u003e3.81\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCOP 4.62\u003c\/td\u003e\n\u003ctd\u003e4.62\u003c\/td\u003e\n\u003ctd\u003e4.72\u003c\/td\u003e\n\u003ctd\u003e4.72\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePerformance parameters at A7\/W55\u003c\/td\u003e\n\u003ctd\u003e\u0026nbsp;\u003c\/td\u003e\n\u003ctd\u003e\u0026nbsp;\u003c\/td\u003e\n\u003ctd\u003e\u0026nbsp;\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal heat output (kW)\u003c\/td\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003ctd\u003e15\u003c\/td\u003e\n\u003ctd\u003e15\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower input (kW)\u003c\/td\u003e\n\u003ctd\u003e2.82\u003c\/td\u003e\n\u003ctd\u003e4.08\u003c\/td\u003e\n\u003ctd\u003e4.08\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCOP 3.54\u003c\/td\u003e\n\u003ctd\u003e3.54\u003c\/td\u003e\n\u003ctd\u003e3.68\u003c\/td\u003e\n\u003ctd\u003e3.68\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling capacity parameters at A35\/W7\u003c\/td\u003e\n\u003ctd\u003e\u0026nbsp;\u003c\/td\u003e\n\u003ctd\u003e\u0026nbsp;\u003c\/td\u003e\n\u003ctd\u003e\u0026nbsp;\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling capacity (kW)\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003ctd\u003e14\u003c\/td\u003e\n\u003ctd\u003e14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower input (kW)\u003c\/td\u003e\n\u003ctd\u003e2.25\u003c\/td\u003e\n\u003ctd\u003e3.87\u003c\/td\u003e\n\u003ctd\u003e3.87\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEER coefficient\u003c\/td\u003e\n\u003ctd\u003e3.56\u003c\/td\u003e\n\u003ctd\u003e3.62\u003c\/td\u003e\n\u003ctd\u003e3.62\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. power consumption (kW)\u003c\/td\u003e\n\u003ctd\u003e5.3\u003c\/td\u003e\n\u003ctd\u003e6.8\u003c\/td\u003e\n\u003ctd\u003e6.8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated current (A)\u003c\/td\u003e\n\u003ctd\u003e32\u003c\/td\u003e\n\u003ctd\u003e32\u003c\/td\u003e\n\u003ctd\u003e32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant\u003c\/td\u003e\n\u003ctd\u003eR32\u003c\/td\u003e\n\u003ctd\u003eR32\u003c\/td\u003e\n\u003ctd\u003eR32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet weight (kg) 75\u003c\/td\u003e\n\u003ctd\u003e75\u003c\/td\u003e\n\u003ctd\u003e147\u003c\/td\u003e\n\u003ctd\u003e147\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (WxDxH) (mm)\u003c\/td\u003e\n\u003ctd\u003e1005x370x800\u003c\/td\u003e\n\u003ctd\u003e1077x377x1460\u003c\/td\u003e\n\u003ctd\u003e1077x377x1460\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSound power level (dB)\u003c\/td\u003e\n\u003ctd\u003e58\u003c\/td\u003e\n\u003ctd\u003e71\u003c\/td\u003e\n\u003ctd\u003e71\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompressor\u003c\/td\u003e\n\u003ctd\u003eInverter from Toshiba\u003c\/td\u003e\n\u003ctd\u003eInverter from Panasonic\u003c\/td\u003e\n\u003ctd\u003eInverter from Panasonic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutdoor temperature range\u003c\/td\u003e\n\u003ctd\u003e-30°C to +48°C\u003c\/td\u003e\n\u003ctd\u003e-30°C to +48°C\u003c\/td\u003e\n\u003ctd\u003e-30°C to +48°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u0026nbsp;\u003c\/p\u003e\n\u003ch3\u003eDownload\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca rel=\"noopener\" title=\"Installation and operation\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0757\/7796\/6428\/files\/Mono_12_18_KW_seria_THERMA_DE_popr_R32.pdf?v=1722232969\" target=\"_blank\" aria-label=\"Besuchen Sie eine Webseite über Montage und Bedienung\"\u003eInstallation and operating instructions\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0757\/7796\/6428\/files\/Energielabel_BLNTA.pdf?v=1722233298\" target=\"_blank\" title=\"BLNTA energy label\" rel=\"noopener\" aria-label=\"Besuchen Sie eine Webseite über BLNTA Energielabel\"\u003eEnergy label\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0757\/7796\/6428\/files\/Technisches_Datenblatt_BLNTA.pdf?v=1722233287\" target=\"_blank\" title=\"BLNTA product data sheet\" rel=\"noopener\" aria-label=\"Besuchen Sie eine Webseite über Produktdatenblatt BLNTA\"\u003eProduct data sheet\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u0026nbsp;\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cstyle type=\"text\/css\"\u003e\n\ttable.tableizer-table {\n\t\tfont-size: 12px;\n\t\tborder: 1px solid #CCC; \n\t\tfont-family: Arial, Helvetica, sans-serif;\n\t} \n\t.tableizer-table td {\n\t\tpadding: 4px;\n\t\tmargin: 3px;\n\t\tborder: 1px solid #CCC;\n\t}\n\t.tableizer-table th {\n\t\tbackground-color: #104E8B; \n\t\tcolor: #FFF;\n\t\tfont-weight: bold;\n\t}\n\u003c\/style\u003e","brand":"Elektromet","offers":[{"title":"Default Title","offer_id":58911465603420,"sku":"LWWT18230","price":3197.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0757\/7796\/6428\/files\/luft-wasser-warmepumpe-terma-5768167.png?v=1770692603","url":"https:\/\/gemashop.de\/en\/products\/luft-wasser-waermepumpe-titan-therm-terma-18-kw-230-v","provider":"GEMA Shop","version":"1.0","type":"link"}