{"product_id":"holzvergaserkessel-mpm-wood-pro-17-8-5-17-kw","title":"MPM Wood Pro 17 wood gasification boiler 8.5–17 kW","description":"\u003cstyle\u003e .product-th{margin-top:2rem}.product-th h2{margin:0 0 1rem}.product-th__table{width:100%;border-collapse:separate;border-spacing:0}.product-th__table td{padding:.95rem 1rem;vertical-align:top}.product-th__label{font-weight:700;width:38%;color:#213670}.product-th__value{color:#1f2937}.product-th__table tr:nth-child(odd) td{background:#f4f7fb}.product-th__table tr:nth-child(even) td{background:#fafbfd} \u003c\/style\u003e \u003cdiv class=\"gema-section\"\u003e \u003ch2\u003eProduct Overview \u0026amp; Application Area\u003c\/h2\u003e \u003cp\u003eThe MPM Wood Pro 17 is a manually fed wood gasification boiler for log wood with an output range of 8.5 to 17 kW. It is intended for hydronic central heating systems and is particularly suitable for single-family homes as well as appropriately sized smaller commercial or trade buildings. The specific boiler output must be determined based on the heat demand or a heating load calculation.\u003c\/p\u003e \u003c\/div\u003e \u003cdiv class=\"gema-section\"\u003e \u003ch2\u003eTechnology \u0026amp; Equipment\u003c\/h2\u003e \u003cp\u003eCombustion operates on the wood gasification principle with separate gasification and combustion zones. The equipment includes a movable cast iron grate, a metal-ceramic burner, and vertical and horizontal heat exchanger passes. Primary and secondary air can be adjusted to the combustion process. The standard version operates with natural chimney draft and a mechanical draft regulator; an electronic combustion control or a fan is not required for the basic operation of the boiler.\u003c\/p\u003e \u003c\/div\u003e \u003cdiv class=\"gema-section\"\u003e \u003ch2\u003eEveryday Benefits\u003c\/h2\u003e \u003cp\u003eThe output switching between minimum and rated operation supports adaptation to the current heat demand. A filling chamber of approximately 60 liters, generously sized doors, a flame viewing window, and easily accessible cleaning areas facilitate loading, monitoring, and regular maintenance. Log wood up to 350 mm in length can be used.\u003c\/p\u003e \u003c\/div\u003e \u003cdiv class=\"gema-section\"\u003e \u003ch2\u003eSystem Integration \u0026amp; Compatibility\u003c\/h2\u003e \u003cp\u003eThe Wood Pro 17 can be used in professionally safeguarded open or closed hot water heating systems. Thanks to its switchable output levels, operation without a mandatory buffer storage tank is constructively possible. However, a thermal storage tank is still recommended for system design; the product-related EU document specifies at least 644 liters for this. To protect against low-temperature corrosion, a return temperature of at least 55 °C must be ensured.\u003c\/p\u003e \u003c\/div\u003e \u003cdiv class=\"product-th\"\u003e \u003ch2\u003eTechnical Data at a Glance\u003c\/h2\u003e \u003ctable class=\"product-th__table\"\u003e \u003ctbody\u003e \u003ctr\u003e\n\u003ctd class=\"product-th__label\"\u003eRated Output\u003c\/td\u003e\n\u003ctd class=\"product-th__value\"\u003e17 kW\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd class=\"product-th__label\"\u003eEfficiency\u003c\/td\u003e\n\u003ctd class=\"product-th__value\"\u003e91.1%\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd class=\"product-th__label\"\u003eEnergy efficiency class\u003c\/td\u003e\n\u003ctd class=\"product-th__value\"\u003eA+\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd class=\"product-th__label\"\u003eEnergy efficiency index (EEI)\u003c\/td\u003e\n\u003ctd class=\"product-th__value\"\u003e118\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd class=\"product-th__label\"\u003eSeasonal space heating energy efficiency\u003c\/td\u003e\n\u003ctd class=\"product-th__value\"\u003e80%\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd class=\"product-th__label\"\u003eBoiler class\u003c\/td\u003e\n\u003ctd class=\"product-th__value\"\u003e5\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd class=\"product-th__label\"\u003eFuel\u003c\/td\u003e\n\u003ctd class=\"product-th__value\"\u003eFirewood\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd class=\"product-th__label\"\u003eMax. firewood length\u003c\/td\u003e\n\u003ctd class=\"product-th__value\"\u003e350 mm\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd class=\"product-th__label\"\u003eMax. operating pressure\u003c\/td\u003e\n\u003ctd class=\"product-th__value\"\u003e3 bar\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd class=\"product-th__label\"\u003eFlue pipe connection\u003c\/td\u003e\n\u003ctd class=\"product-th__value\"\u003e178 mm\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd class=\"product-th__label\"\u003eFlow \/ Return\u003c\/td\u003e\n\u003ctd class=\"product-th__value\"\u003e1 1\/2 inches\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd class=\"product-th__label\"\u003eBuffer tank recommended\u003c\/td\u003e\n\u003ctd class=\"product-th__value\"\u003eYes, reference volume at least 644 liters\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd class=\"product-th__label\"\u003eOverall dimensions H × W × D\u003c\/td\u003e\n\u003ctd class=\"product-th__value\"\u003e1200 × 475 × 1025 mm\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd class=\"product-th__label\"\u003eWeight\u003c\/td\u003e\n\u003ctd class=\"product-th__value\"\u003eapprox. 260 kg\u003c\/td\u003e\n\u003c\/tr\u003e \u003c\/tbody\u003e \u003c\/table\u003e \u003c\/div\u003e \u003cdiv class=\"gema-section\"\u003e \u003ch2\u003eInstallation\u003c\/h2\u003e \u003cp\u003eInstallation, hydraulic connection, flue gas connection, and safety equipment must be carried out by appropriately qualified specialist personnel. The chimney cross-section and chimney height must be matched to the required draft of the boiler. In the hydraulic system, suitable return temperature boosting must be provided. For closed systems, the required pressure and overtemperature safety devices must be implemented in accordance with standards.\u003c\/p\u003e \u003c\/div\u003e \u003cdiv class=\"gema-section\"\u003e \u003ch2\u003eNotes\u003c\/h2\u003e \u003cp\u003eFor stable gasification operation, dry, seasoned split logs are required. The return temperature should be at least 55 °C. The manufacturer\u0026#39;s documents contain different specifications regarding the maximum operating temperature; therefore, no definitive value is included in the GEMA metadata for this. Pumps and other components of the heating system may require an electrical supply independent of the mechanical boiler operation.\u003c\/p\u003e \u003c\/div\u003e \u003cdiv class=\"gema-section\"\u003e \u003ch2\u003eScope of delivery\u003c\/h2\u003e \u003cul\u003e \u003cli\u003eMPM Wood Pro 17 wood gasification boiler\u003c\/li\u003e \u003cli\u003eOperating instructions\u003c\/li\u003e \u003cli\u003eWarranty booklet\u003c\/li\u003e \u003cli\u003eAnalog thermometer\u003c\/li\u003e \u003cli\u003eCleaning tools\u003c\/li\u003e \u003cli\u003eTurbulator \/ flue insert\u003c\/li\u003e \u003cli\u003eMechanical draft regulator\u003c\/li\u003e \u003c\/ul\u003e \u003c\/div\u003e","brand":"MPM","offers":[{"title":"Default Title","offer_id":58721474511196,"sku":"MPMWP17","price":2599.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0757\/7796\/6428\/files\/gema-shop-mpm-wood-pro-festbrennstoffkessel_cfb04e52-9493-4d2c-88ec-20418d4a575f.jpg?v=1787909229","url":"https:\/\/gemashop.de\/en\/products\/holzvergaserkessel-mpm-wood-pro-17-8-5-17-kw","provider":"GEMA Shop","version":"1.0","type":"link"}