{"product_id":"holzvergaserkessel-mpm-wood-plus-26-kw","title":"MPM Wood Plus 26 kW wood gasification boiler","description":"\u003cdiv class=\"gema-section\"\u003e \u003ch2\u003eMPM Wood Plus 26: Product Overview \u0026amp; Application Area\u003c\/h2\u003e \u003cp\u003eThe MPM Wood Plus 26 is a manually fed wood gasification boiler with a nominal heat output of 26 kW for dry hardwood logs. It is designed for integration into water-based central heating systems and is suitable for residential buildings as well as suitable commercial and trade areas. The specific boiler output must be matched to the calculated heating load of the building.\u003c\/p\u003e \u003c\/div\u003e \u003cdiv class=\"gema-section\"\u003e \u003ch2\u003eTechnology \u0026amp; Equipment\u003c\/h2\u003e \u003cp\u003eWood gasification takes place in separate functional zones: In the loading chamber, the fuel is degassed, and the resulting wood gases are then burned in a ceramic combustion chamber. The construction includes a movable cast iron grate, a metal-ceramic burner, and vertically arranged flue gas channels with a turbulence device. Primary and secondary air can be regulated. The standard version operates with natural chimney draft and mechanical draft control.\u003c\/p\u003e \u003c\/div\u003e \u003cdiv class=\"gema-section\"\u003e \u003ch2\u003eEveryday Benefits\u003c\/h2\u003e \u003cp\u003eThe loading chamber holds approximately 120 liters or about 40 kg of fuel. For the 26 kW version, a fuel consumption of about 7 kg per hour and a burn time of around six hours are specified. A flue gas extraction channel in the loading chamber supports reloading and reduces the escape of flue gases into the boiler room. A flame viewer and easily accessible cleaning areas support monitoring and regular maintenance.\u003c\/p\u003e \u003c\/div\u003e \u003cdiv class=\"gema-section\"\u003e \u003ch2\u003eSystem Integration \u0026amp; Compatibility\u003c\/h2\u003e \u003cp\u003eThe MPM Wood Plus 26 is operated in conjunction with a buffer tank; for the 26 kW version, at least 1000 liters are intended. The return temperature to the boiler must be at least 55 °C, which is why a suitable return temperature boost is required. The boiler can be used in open as well as appropriately safeguarded closed heating systems. For closed systems, suitable devices for pressure and temperature protection as well as for reliable dissipation of excess heat must be provided.\u003c\/p\u003e \u003c\/div\u003e \u003cstyle\u003e .product-th{margin-top:2rem}.product-th h2{margin:0 0 1rem}.product-th__table{width:100%;border-collapse:separate;border-spacing:0}.product-th__table td{padding:.95rem 1rem;vertical-align:top}.product-th__label{font-weight:700;width:38%;color:#213670}.product-th__value{color:#1f2937}.product-th__table tr:nth-child(odd) td{background:#f4f7fb}.product-th__table tr:nth-child(even) td{background:#fafbfd} \u003c\/style\u003e \u003cdiv class=\"product-th\"\u003e \u003ch2\u003eTechnical Data at a Glance\u003c\/h2\u003e \u003ctable class=\"product-th__table\"\u003e \u003ctbody\u003e \u003ctr\u003e\n\u003ctd class=\"product-th__label\"\u003eNominal heat output\u003c\/td\u003e\n\u003ctd class=\"product-th__value\"\u003e26 kW\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd class=\"product-th__label\"\u003eFuel\u003c\/td\u003e\n\u003ctd class=\"product-th__value\"\u003eHardwood log wood\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd class=\"product-th__label\"\u003eCombustion technology\u003c\/td\u003e\n\u003ctd class=\"product-th__value\"\u003eWood gasification\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd class=\"product-th__label\"\u003eThermal efficiency\u003c\/td\u003e\n\u003ctd class=\"product-th__value\"\u003e90.1%\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd class=\"product-th__label\"\u003eEnergy efficiency class\u003c\/td\u003e\n\u003ctd class=\"product-th__value\"\u003eA+\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd class=\"product-th__label\"\u003eEnergy efficiency index EEI\u003c\/td\u003e\n\u003ctd class=\"product-th__value\"\u003e116\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd class=\"product-th__label\"\u003eSeasonal energy efficiency\u003c\/td\u003e\n\u003ctd class=\"product-th__value\"\u003e79%\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd class=\"product-th__label\"\u003eLog length\u003c\/td\u003e\n\u003ctd class=\"product-th__value\"\u003eapprox. 330 mm\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd class=\"product-th__label\"\u003eBoiler class\u003c\/td\u003e\n\u003ctd class=\"product-th__value\"\u003e5\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd class=\"product-th__label\"\u003eOperating temperature\u003c\/td\u003e\n\u003ctd class=\"product-th__value\"\u003e60–90 °C\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd class=\"product-th__label\"\u003eMin. return temperature\u003c\/td\u003e\n\u003ctd class=\"product-th__value\"\u003e55 °C\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd class=\"product-th__label\"\u003eMax. flow temperature\u003c\/td\u003e\n\u003ctd class=\"product-th__value\"\u003e90 °C\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd class=\"product-th__label\"\u003eMax. operating pressure\u003c\/td\u003e\n\u003ctd class=\"product-th__value\"\u003e1.5 bar\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd class=\"product-th__label\"\u003eFlue gas temperature at rated output\u003c\/td\u003e\n\u003ctd class=\"product-th__value\"\u003e125–140 °C\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd class=\"product-th__label\"\u003eRequired flue draft\u003c\/td\u003e\n\u003ctd class=\"product-th__value\"\u003eapprox. 30 Pa\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd class=\"product-th__label\"\u003eFlue pipe connection\u003c\/td\u003e\n\u003ctd class=\"product-th__value\"\u003eØ 178 mm\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd class=\"product-th__label\"\u003eBuffer tank\u003c\/td\u003e\n\u003ctd class=\"product-th__value\"\u003eat least 1000 liters\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd class=\"product-th__label\"\u003eHeight\u003c\/td\u003e\n\u003ctd class=\"product-th__value\"\u003e1183 mm\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd class=\"product-th__label\"\u003eWidth\u003c\/td\u003e\n\u003ctd class=\"product-th__value\"\u003e655 mm\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd class=\"product-th__label\"\u003eDepth\u003c\/td\u003e\n\u003ctd class=\"product-th__value\"\u003e1220 mm\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd class=\"product-th__label\"\u003eWeight\u003c\/td\u003e\n\u003ctd class=\"product-th__value\"\u003eapprox. 450 kg\u003c\/td\u003e\n\u003c\/tr\u003e \u003c\/tbody\u003e \u003c\/table\u003e \u003c\/div\u003e \u003cdiv class=\"gema-section\"\u003e \u003ch2\u003eInstallation\u003c\/h2\u003e \u003cp\u003eInstallation, hydraulic connection, and chimney connection must be carried out by appropriately qualified specialist personnel. For the 26 kW version, a buffer tank with a minimum capacity of 1000 liters must be provided, and the system return must be protected by a suitable return temperature boost to at least 55 °C. The chimney, hydraulic components, and safety devices must be matched to the specific system configuration.\u003c\/p\u003e \u003c\/div\u003e \u003cdiv class=\"gema-section\"\u003e \u003ch2\u003eNotes\u003c\/h2\u003e \u003cp\u003eDry hardwood logs are intended as fuel. A moisture content of about 12 to 20% is recommended. Continuous operation with wet wood or excessively low boiler and return temperatures can promote condensation, tar formation, and low-temperature corrosion. The boiler and flue gas passages must be cleaned and inspected regularly in accordance with the operating conditions.\u003c\/p\u003e \u003c\/div\u003e \u003cdiv class=\"gema-section\"\u003e \u003ch2\u003eScope of delivery\u003c\/h2\u003e \u003cul\u003e \u003cli\u003eMPM Wood Plus 26 wood gasification boiler\u003c\/li\u003e \u003cli\u003eOperating instructions\u003c\/li\u003e \u003cli\u003eWarranty card\u003c\/li\u003e \u003c\/ul\u003e \u003c\/div\u003e","brand":"MPM","offers":[{"title":"Default Title","offer_id":54128565092700,"sku":"MPMWP26","price":3195.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0757\/7796\/6428\/files\/gema-shop-mpm-wood-plus-26-holzvergaserkessel_25f5efd0-2207-456d-be1b-2d290d3ad55f.jpg?v=1787126747","url":"https:\/\/gemashop.de\/en\/products\/holzvergaserkessel-mpm-wood-plus-26-kw","provider":"GEMA Shop","version":"1.0","type":"link"}