{"product_id":"attack-slx-55-profi-holzvergaser-55-kw","title":"Wood gasifier 55 kW ATTACK SLX 55 Profi","description":"\u003cp data-start=\"346\" data-end=\"792\"\u003eThe \u003cstrong data-start=\"350\" data-end=\"373\"\u003eATTACK SLX 55 PROFI\u003c\/strong\u003e This is a particularly powerful wood gasification boiler with a nominal output of 55 kW for the efficient and low-emission combustion of logs. It is ideally suited for large apartment buildings, commercial properties, or agricultural operations with very high heat demands. Its robust construction and tested performance data according to EN 303-5 make it a reliable solution in the output segment above 50 kW.\u003c\/p\u003e  \u003chr data-start=\"794\" data-end=\"797\"\u003e  \u003ch2 data-start=\"799\" data-end=\"823\"\u003eHighlights\/Advantages\u003c\/h2\u003e  \u003cp data-start=\"825\" data-end=\"1175\"\u003e⭐  \u003cstrong data-start=\"827\" data-end=\"849\"\u003e55 kW nominal power\u003c\/strong\u003e – for very large residential and commercial buildings\u003cbr data-start=\"891\" data-end=\"894\"\u003e⭐  \u003cstrong data-start=\"896\" data-end=\"924\"\u003eWood gasifier technology\u003c\/strong\u003e – efficient two-stage combustion\u003cbr data-start=\"961\" data-end=\"964\"\u003e⭐  \u003cstrong data-start=\"966\" data-end=\"991\"\u003eTested according to EN 303-5\u003c\/strong\u003e – Standard-compliant operation for logs\u003cbr data-start=\"1029\" data-end=\"1032\"\u003e⭐  \u003cstrong data-start=\"1034\" data-end=\"1063\"\u003eRobust steel construction\u003c\/strong\u003e – durable and easy to service\u003cbr data-start=\"1097\" data-end=\"1100\"\u003e⭐  \u003cstrong data-start=\"1102\" data-end=\"1145\"\u003eTurbulator system with cleaning lever\u003c\/strong\u003e – optimized heat transfer\u003c\/p\u003e  \u003chr data-start=\"1177\" data-end=\"1180\"\u003e  \u003ch1 data-start=\"1182\" data-end=\"1222\"\u003eATTACK SLX 55 PROFI wood gasifier 55 kW\u003c\/h1\u003e  \u003ch2 data-start=\"1224\" data-end=\"1254\"\u003eArea of ​​application \u0026amp; Target audience\u003c\/h2\u003e  \u003cp data-start=\"1256\" data-end=\"1395\"\u003eThe ATTACK SLX 55 PROFI is a \u003cstrong data-start=\"1288\" data-end=\"1337\"\u003eHot water boiler for solid fuels (wood)\u003c\/strong\u003e With manual loading. It is particularly suitable for:\u003c\/p\u003e  \u003cul data-start=\"1397\" data-end=\"1603\"\u003e  \u003cli data-start=\"1397\" data-end=\"1425\"\u003e  \u003cp data-start=\"1399\" data-end=\"1425\"\u003elarge apartment buildings\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-start=\"1426\" data-end=\"1466\"\u003e  \u003cp data-start=\"1428\" data-end=\"1466\"\u003ecommercial and industrial buildings\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-start=\"1467\" data-end=\"1498\"\u003e  \u003cp data-start=\"1469\" data-end=\"1498\"\u003eagricultural facilities\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-start=\"1499\" data-end=\"1540\"\u003e  \u003cp data-start=\"1501\" data-end=\"1540\"\u003eHeating systems with high power requirements\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-start=\"1541\" data-end=\"1603\"\u003e  \u0026amp;Renovation projects with a suitably sized chimney\u003c\/p\u003e  \u003c\/li\u003e  \u003c\/ul\u003e  \u003cp data-start=\"1605\" data-end=\"1685\"\u003eThe preferred fuel type is \u003cstrong data-start=\"1639\" data-end=\"1684\"\u003eLogs with a moisture content ≤ 25%\u003c\/strong\u003e.\u003c\/p\u003e  \u003chr data-start=\"1687\" data-end=\"1690\"\u003e  \u003ch2 data-start=\"1692\" data-end=\"1713\"\u003eEveryday benefits\u003c\/h2\u003e  \u003cp data-start=\"1715\" data-end=\"1907\"\u003eThe proven wood gasification principle ensures efficient energy utilization. The wood is first gasified, and the resulting wood gases are then completely combusted. This leads to:\u003c\/p\u003e  \u003cul data-start=\"1909\" data-end=\"2055\"\u003e  \u003cli data-start=\"1909\" data-end=\"1939\"\u003e  \u003cp data-start=\"1911\" data-end=\"1939\"\u003ehigh fuel utilization\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-start=\"1940\" data-end=\"1968\"\u003e  \u003cp data-start=\"1942\" data-end=\"1968\"\u003estable power output\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-start=\"1969\" data-end=\"2002\"\u003e  \u003cp data-start=\"1971\" data-end=\"2002\"\u003ereduced pollutant emissions\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-start=\"2003\" data-end=\"2055\"\u003e  \u003cp data-start=\"2005\" data-end=\"2055\"\u003eeconomical operation even with high heating load\u003c\/p\u003e  \u003c\/li\u003e  \u003c\/ul\u003e  \u003cp data-start=\"2057\" data-end=\"2182\"\u003eThe integrated turbulators improve heat transfer and can be conveniently cleaned via the lever mechanism.\u003c\/p\u003e  \u003chr data-start=\"2184\" data-end=\"2187\"\u003e  \u003ch2 data-start=\"2189\" data-end=\"2213\"\u003eTechnology \u0026amp; equipment\u003c\/h2\u003e  \u003cul data-start=\"2215\" data-end=\"2580\"\u003e  \u003cli data-start=\"2215\" data-end=\"2259\"\u003e  \u003cp data-start=\"2217\" data-end=\"2259\"\u003eBoiler type: Wood gasification hot water boiler\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-start=\"2260\" data-end=\"2294\"\u003e  \u003cp data-start=\"2262\" data-end=\"2294\"\u003eFuel feed: manual\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-start=\"2295\" data-end=\"2336\"\u003e  \u003cp data-start=\"2297\" data-end=\"2336\"\u003eAdjustable primary and secondary air\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-start=\"2337\" data-end=\"2375\"\u003e  \u003cp data-start=\"2339\" data-end=\"2375\"\u003eFan-assisted combustion\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-start=\"2376\" data-end=\"2413\"\u003e  \u003cp data-start=\"2378\" data-end=\"2413\"\u003eTurbulators in the tube heat exchanger\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-start=\"2414\" data-end=\"2457\"\u003e  \u003cp data-start=\"2416\" data-end=\"2457\"\u003eThermal safety device required\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-start=\"2458\" data-end=\"2489\"\u003e  \u003cp data-start=\"2460\" data-end=\"2489\"\u003eMaximum operating pressure: 2.5 bar\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-start=\"2490\" data-end=\"2545\"\u003e  \u003cp data-start=\"2492\" data-end=\"2545\"\u003eMinimum chimney diameter: 150 mm (200 mm recommended)\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-start=\"2546\" data-end=\"2580\"\u003e  \u003cp data-start=\"2548\" data-end=\"2580\"\u003eRecommended chimney draft: 23–30 Pa\u003c\/p\u003e  \u003c\/li\u003e  \u003c\/ul\u003e  \u003cp data-start=\"2582\" data-end=\"2712\"\u003eFor a long service life, the return temperature must remain consistently above 65 °C. Recommended boiler operating temperature: 80–85 °C.\u003c\/p\u003e  \u003chr data-start=\"2714\" data-end=\"2717\"\u003e  \u003ch2 data-start=\"2719\" data-end=\"2740\"\u003eEfficiency \u0026amp; Environment\u003c\/h2\u003e  \u003cp data-start=\"2742\" data-end=\"2827\"\u003eThe ATTACK SLX 55 PROFI is designed for operation with logs in accordance with EN 303-5.\u003c\/p\u003e  \u003cul data-start=\"2829\" data-end=\"2993\"\u003e  \u003cli data-start=\"2829\" data-end=\"2857\"\u003e  \u003cp data-start=\"2831\" data-end=\"2857\"\u003eNominal heat output: 55 kW\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-start=\"2858\" data-end=\"2891\"\u003e  \u003cp data-start=\"2860\" data-end=\"2891\"\u003eMinimum heat output: 27.5 kW\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-start=\"2892\" data-end=\"2941\"\u003e  \u003cp data-start=\"2894\" data-end=\"2941\"\u003eEfficiency: not specified according to the data sheet\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-start=\"2942\" data-end=\"2993\"\u003e  \u003cp data-start=\"2944\" data-end=\"2993\"\u003eEmission values: not specified according to the data sheet\u003c\/p\u003e  \u003c\/li\u003e  \u003c\/ul\u003e  \u003cp data-start=\"2995\" data-end=\"3095\"\u003eCompliance with the normative requirements is ensured according to the manufacturer's specifications for the SLX PROFI series.\u003c\/p\u003e  \u003chr data-start=\"3097\" data-end=\"3100\"\u003e  \u003ch2 data-start=\"3102\" data-end=\"3139\"\u003ecompatibility \u0026amp; System integration\u003c\/h2\u003e  \u003cp data-start=\"3141\" data-end=\"3232\"\u003eFor standard-compliant plant operation, the SLX 55 PROFI is typically combined with:\u003c\/p\u003e  \u003cul data-start=\"3234\" data-end=\"3395\"\u003e  \u003cli data-start=\"3234\" data-end=\"3280\"\u003e  \u003cp data-start=\"3236\" data-end=\"3280\"\u003eadequately sized buffer storage\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-start=\"3281\" data-end=\"3320\"\u003e  \u003cp data-start=\"3283\" data-end=\"3320\"\u003eReturn flow booster\/mixing device\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-start=\"3321\" data-end=\"3352\"\u003e  \u003cp data-start=\"3323\" data-end=\"3352\"\u003eThermal safety device\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-start=\"3353\" data-end=\"3374\"\u003e  \u003cp data-start=\"3355\" data-end=\"3374\"\u003eSafety valve\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-start=\"3375\" data-end=\"3395\"\u003e  \u003cp data-start=\"3377\" data-end=\"3395\"\u003eExpansion vessel\u003c\/p\u003e  \u003c\/li\u003e  \u003c\/ul\u003e  \u003cp data-start=\"3397\" data-end=\"3514\"\u003eSuitable \u003cstrong data-start=\"3406\" data-end=\"3473\"\u003eBuffer tanks, hydraulic components and safety groups\u003c\/strong\u003e You can find them in our product range at gemashop.de.\u003c\/p\u003e  \u003chr data-start=\"3516\" data-end=\"3519\"\u003e  \u003ch2 data-start=\"3521\" data-end=\"3540\"\u003eTechnical data\u003c\/h2\u003e  \u003cdiv class=\"TyagGW_tableContainer\"\u003e  \u003cdiv class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e  \u003ctable data-start=\"3542\" data-end=\"3953\" class=\"w-fit min-w-(--thread-content-width)\"\u003e  \u003cthead data-start=\"3542\" data-end=\"3560\"\u003e  \u003ctr data-start=\"3542\" data-end=\"3560\"\u003e  \u003cth data-start=\"3542\" data-end=\"3552\" data-col-size=\"sm\" class=\"\"\u003efeature\u003c\/th\u003e  \u003cth data-start=\"3552\" data-end=\"3560\" data-col-size=\"sm\" class=\"\"\u003eValue\u003c\/th\u003e  \u003c\/tr\u003e  \u003c\/thead\u003e  \u003ctbody data-start=\"3580\" data-end=\"3953\"\u003e  \u003ctr data-start=\"3580\" data-end=\"3610\"\u003e  \u003ctd data-start=\"3580\" data-end=\"3593\" data-col-size=\"sm\"\u003eManufacturer\u003c\/td\u003e  \u003ctd data-start=\"3593\" data-end=\"3610\" data-col-size=\"sm\"\u003eATTACK s.r.o.\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr data-start=\"3611\" data-end=\"3636\"\u003e  \u003ctd data-start=\"3611\" data-end=\"3620\" data-col-size=\"sm\"\u003eModel\u003c\/td\u003e  \u003ctd data-start=\"3620\" data-end=\"3636\" data-col-size=\"sm\"\u003eSLX 55 PROFI\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr data-start=\"3637\" data-end=\"3683\"\u003e  \u003ctd data-start=\"3637\" data-end=\"3650\" data-col-size=\"sm\"\u003eProduct type\u003c\/td\u003e  \u003ctd data-start=\"3650\" data-end=\"3683\" data-col-size=\"sm\"\u003eWood gasification hot water boiler\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr data-start=\"3684\" data-end=\"3725\"\u003e  \u003ctd data-start=\"3684\" data-end=\"3697\" data-col-size=\"sm\"\u003efuel\u003c\/td\u003e  \u003ctd data-start=\"3697\" data-end=\"3725\" data-col-size=\"sm\"\u003eFirewood ≤ 25% moisture content\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr data-start=\"3726\" data-end=\"3755\"\u003e  \u003ctd data-start=\"3726\" data-end=\"3746\" data-col-size=\"sm\"\u003eNominal heat output\u003c\/td\u003e  \u003ctd data-start=\"3746\" data-end=\"3755\" data-col-size=\"sm\"\u003e55 kW\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr data-start=\"3756\" data-end=\"3790\"\u003e  \u003ctd data-start=\"3756\" data-end=\"3779\" data-col-size=\"sm\"\u003eMinimum heat output\u003c\/td\u003e  \u003ctd data-start=\"3779\" data-end=\"3790\" data-col-size=\"sm\"\u003e27.5 kW\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr data-start=\"3791\" data-end=\"3823\"\u003e  \u003ctd data-start=\"3791\" data-end=\"3812\" data-col-size=\"sm\"\u003eMaximum operating pressure.\u003c\/td\u003e  \u003ctd data-start=\"3812\" data-end=\"3823\" data-col-size=\"sm\"\u003e2.5 bar\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr data-start=\"3824\" data-end=\"3861\"\u003e  \u003ctd data-start=\"3824\" data-end=\"3851\" data-col-size=\"sm\"\u003eMinimum chimney diameter\u003c\/td\u003e  \u003ctd data-start=\"3851\" data-end=\"3861\" data-col-size=\"sm\"\u003e150 mm\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr data-start=\"3862\" data-end=\"3897\"\u003e  \u003ctd data-start=\"3862\" data-end=\"3885\" data-col-size=\"sm\"\u003eRecommended chimney draft\u003c\/td\u003e  \u003ctd data-start=\"3885\" data-end=\"3897\" data-col-size=\"sm\"\u003e23 Pa\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr data-start=\"3898\" data-end=\"3933\"\u003e  \u003ctd data-start=\"3898\" data-end=\"3922\" data-col-size=\"sm\"\u003eFuel feed\u003c\/td\u003e  \u003ctd data-start=\"3922\" data-end=\"3933\" data-col-size=\"sm\"\u003emanually\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr data-start=\"3934\" data-end=\"3953\"\u003e  \u003ctd data-start=\"3934\" data-end=\"3941\" data-col-size=\"sm\"\u003estandard\u003c\/td\u003e  \u003ctd data-start=\"3941\" data-end=\"3953\" data-col-size=\"sm\"\u003eEN 303-5\u003c\/td\u003e  \u003c\/tr\u003e  \u003c\/tbody\u003e  \u003c\/table\u003e  \u003c\/div\u003e  \u003c\/div\u003e  \u003chr data-start=\"3955\" data-end=\"3958\"\u003e  \u003ch2 data-start=\"3960\" data-end=\"3975\"\u003eScope of delivery\u003c\/h2\u003e  \u003cul data-start=\"3977\" data-end=\"4058\"\u003e  \u003cli data-start=\"3977\" data-end=\"4013\"\u003e  \u003cp data-start=\"3979\" data-end=\"4013\"\u003eATTACK SLX 55 PROFI wood gasifier\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-start=\"4014\" data-end=\"4037\"\u003e  \u003cp data-start=\"4016\" data-end=\"4037\"\u003eUser manual\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-start=\"4038\" data-end=\"4058\"\u003e  \u003cp data-start=\"4040\" data-end=\"4058\"\u003eAssembly instructions\u003c\/p\u003e  \u003c\/li\u003e  \u003c\/ul\u003e  \u003chr data-start=\"4060\" data-end=\"4063\"\u003e  \u003ch2 data-start=\"4065\" data-end=\"4098\"\u003eAssembly \u0026amp; Safety instructions\u003c\/h2\u003e  \u003cp data-start=\"4100\" data-end=\"4202\"\u003eInstallation and commissioning must only be carried out by a qualified specialist company.\u003c\/p\u003e  \u003cp data-start=\"4204\" data-end=\"4222\"\u003eImportant instructions:\u003c\/p\u003e  \u003cul data-start=\"4224\" data-end=\"4455\"\u003e  \u003cli data-start=\"4224\" data-end=\"4276\"\u003e  \u003cp data-start=\"4226\" data-end=\"4276\"\u003eThermal safety device absolutely necessary\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-start=\"4277\" data-end=\"4343\"\u003e  \u003cp data-start=\"4279\" data-end=\"4343\"\u003eReturn temperature boost necessary to prevent condensation\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-start=\"4344\" data-end=\"4381\"\u003e  \u003cp data-start=\"4346\" data-end=\"4381\"\u003eCompliance with chimney requirements\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-start=\"4382\" data-end=\"4455\"\u003e  \u003cp data-start=\"4384\" data-end=\"4455\"\u003eRegular cleaning of ash box, turbulators and heat exchangers\u003c\/p\u003e  \u003c\/li\u003e  \u003c\/ul\u003e  \u003cp data-start=\"4457\" data-end=\"4525\"\u003eThe warranty may be limited if the installation is improper.\u003c\/p\u003e  \u003chr data-start=\"4527\" data-end=\"4530\"\u003e  \u003ch2 data-start=\"4532\" data-end=\"4538\"\u003eFAQ\u003c\/h2\u003e  \u003cp data-start=\"4540\" data-end=\"4633\"\u003e\u003cstrong data-start=\"4540\" data-end=\"4594\"\u003e1. What performance does the ATTACK SLX 55 PROFI offer?\u003c\/strong\u003e\u003cbr data-start=\"4594\" data-end=\"4597\"\u003eThe nominal heat output is 55 kW.\u003c\/p\u003e  \u003cp data-start=\"4635\" data-end=\"4737\"\u003e\u003cstrong data-start=\"4635\" data-end=\"4674\"\u003e2. Which fuel is permitted?\u003c\/strong\u003e\u003cbr data-start=\"4674\" data-end=\"4677\"\u003eFirewood with a maximum moisture content of 25%, 12–20% recommended.\u003c\/p\u003e  \u003cp data-start=\"4739\" data-end=\"4895\"\u003e\u003cstrong data-start=\"4739\" data-end=\"4782\"\u003e3. Is a buffer storage tank required?\u003c\/strong\u003e\u003cbr data-start=\"4782\" data-end=\"4785\"\u003eFor efficient and compliant operation, a sufficiently sized buffer storage tank is recommended.\u003c\/p\u003e  \u003cp data-start=\"4897\" data-end=\"4995\"\u003e\u003cstrong data-start=\"4897\" data-end=\"4937\"\u003e4. What are the chimney requirements?\u003c\/strong\u003e\u003cbr data-start=\"4937\" data-end=\"4940\"\u003eAt least 150 mm diameter and a tension of 23–30 Pa.\u003c\/p\u003e  \u003cp data-start=\"4997\" data-end=\"5060\"\u003e\u003cstrong data-start=\"4997\" data-end=\"5041\"\u003e5. What is the maximum permissible operating pressure?\u003c\/strong\u003e\u003cbr data-start=\"5041\" data-end=\"5044\"\u003eMaximum 2.5 bar.\u003c\/p\u003e  \u003cp data-start=\"5062\" data-end=\"5201\"\u003e\u003cstrong data-start=\"5062\" data-end=\"5109\"\u003e6. How often is cleaning necessary?\u003c\/strong\u003e\u003cbr data-start=\"5109\" data-end=\"5112\"\u003eEmpty the ash box daily, and clean the heat exchanger and turbulators regularly according to the operating instructions.\u003c\/p\u003e  \u003chr data-start=\"5203\" data-end=\"5206\"\u003e  \u003ch2 data-start=\"5208\" data-end=\"5216\"\u003eConclusion\u003c\/h2\u003e  \u003cp data-start=\"5218\" data-end=\"5537\"\u003eThe \u003cstrong data-start=\"5222\" data-end=\"5251\"\u003eATTACK SLX 55 PROFI 55 kW\u003c\/strong\u003e This is the right choice for very large buildings with high heating demands. Its robust construction, proven wood gasification technology, and standards-compliant operation make it a reliable solution for high-performance wood heating systems. Order now and rely on powerful heating performance with logs.\u003c\/p\u003e","brand":"Attack","offers":[{"title":"Default Title","offer_id":47790488879452,"sku":"ASLXP55","price":5190.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0757\/7796\/6428\/files\/SLXprofi-webrender.webp?v=1774512395","url":"https:\/\/gemashop.de\/en\/products\/attack-slx-55-profi-wood-carburettor-55-kw-2","provider":"GEMA Shop","version":"1.0","type":"link"}